Echo X750109-290 Blower User Manual


 
17
POWER BLOWER
OPERATORS MANUAL
AIR FILTER
Level 1.
NOTE
Clean daily.
1. Close choke (Cold Start Position). This prevents dirt from
entering the carburetor throat when the air filter is removed.
Brush accumulated dirt from the air cleaner area.
2. To take out a air filter, loosen both clamps of air cleaner and
remove filter cover as shown.
3. Clean and inspect the element for damage. If element is fuel
soaked and very dirty, replace it.
4. If element can be cleaned and reused, be certain it:
•still fits the cavity in the air cleaner cover.
•is installed with the original side out.
FUEL FILTER
Level 1.
WARNING DANGER
Fuel is VERY flammable. Use extreme care when mixing, storing
or handling.
1. Use a clean rag to remove loose dirt from around fuel cap and
empty fuel tank.
2. Use the “fuel line hook” to pull the fuel line and filter from the
tank.
3. Remove the filter from the line and install the new filter.
Fuel filter
Air cleaner cover
Element
Clamp
CHECK FUEL SYSTEM
Level 1 or 3.
1. Check before every use. (Level 1)
2. After refueling make sure fuel does not leak or exude from around
fuel pipe, fuel grommet or fuel tank cap. (Level 1)
3. In case of fuel leakage or exudation there is a danger of fire. Stop
using the machine immediately and request your dealer to inspect
or replace. (Level 3)