Echo X750109-290 Blower User Manual


 
14
OPERATION
- Provide all operators of this equipment with the Operator’s Manual
and instructions for safe operation.
- Check unit for loose nuts, bolts and screws daily.
- Recoil starter: Use short pulls - only 1/2 - 2/3 of rope length for
starting. Do not allow the rope to snap back in. Always hold the unit
firmly.
- Rotate spring loaded throttle handle downward to a comfortable
operating position.
STARTING COLD ENGINE
WARNING DANGER
When engine is started, confirm if there is not any abnormal
vibration or sound. If there is abnormal vibration or sound, ask your
dealer to repair.
1. Turn switch to “RUN” position.
2. Close choke (move choke lever down) and pull recoil starter
handle until engine fires.
3. Open choke and if necessary, restart engine.
NOTE
Allow engine to warm up before use.
STARTING WARM ENGINE
1. Turn switch to “RUN” position.
2. Move throttle lever to start/idle position, pull recoil starter handle
5 times and engine should start. Do not use choke.
NOTE
If engine does not start after 4 pulls, use cold start procedures.
STOPPING ENGINE
1. Move throttle lever to idle position and allow engine to run at idle
for a few minutes.
2. Move switch to “STOP” position.
WARNING DANGER
If engine does not stop, move choke lever to closed position to stall
engine. Check and repair stop switch before starting engine again or
serious personal injury may result.
Open choke
Close choke
Recoil starter handle
Choke lever
RUN
STOP
Idling
High speed
START