Echo PAS-225 Blower User Manual


 
26
D
A
B
B
E
A
C
D
F
Drive Shaft Upper
1. Loosen clamping knob (A).
2. Pull locator pin (B) and rotate 1/4 turn counter clockwise to lockout
position.
3. Remove attachment.
4. Remove coupler (E) from upper drive shaft assembly by loosening
clamping screw (C) and removing set screw (D).
5. Remove upper ex cable (F), wipe clean, and apply a thin coating of
1/2 oz. (15ml) of grease.
6. Install cable. Make sure that the ex cable fully engages into the
clutch square drive socket.
7. Slide coupler on upper drive shaft until fully seated, and align set
screw hole in coupling with hole in upper drive shaft.
8. Install and tighten set screw (D), and tighten clamping screw (C).
1. Cut one piece of line to recommended length.
.080 (2.0 mm) dia. – 10’ (3 m)
.095 (2.4 mm) dia. – 10’ (3 m)
nylon lIne replacement
2. Align arrows on top of knob with openings in eyelets.
3. Insert one end of trimmer line into an eyelet, and push line equal
distance through trimmer head.