lubrIcatIon
Level 1.
Parts Required: POWER BLENDX
TM
8 oz. (P/N 91014) or
Lithium Base Grease.
Gear Housing
1. Clean all loose debris from gear box.
2. Remove plug (A) and check level of grease.
3. Add grease if necessary. DO NOT over-ll.
Drive Shaft (Lower)
(Trimmer Attachment Only)
IMPORTANT
Lower and upper drive shaft must be lubricated with high tem-
perature automotive grease every 25 hours of operation, otherwise
drive shaft assembly overheating and failure can result.
1. Loosen two (2) screws (B) and remove center locating screw (C).
Pull gear box and shield from drive shaft housing.
2. Pull exible cable from the drive shaft housing, wipe clean and
re-coat with a thin coating [15 ml (1/2 oz.)] of POWER BLEND-
X
TM
.
3. Slide the exible cable back in the drive housing. DO NOT get
dirt on the ex cable.
4. Install the gear housing and shield assembly.
B
C
D
IMPORTANT
Flat edge of washers (D) must be against drive shaft.