Dynasty Spas Elite System D-3000 Hot Tub User Manual


 
If the high limit sensor detects 40 F at the heater, then the pumps
and blower (if installed) automatically activates to provide freeze
protection. The equipment stays on until the sensor detects 45 F at the
heater. Freeze protection is activated regardless of the spa's status.
In colder climates, an optional additional freeze sensor may be added
to protect against freeze conditions. See your dealer for details.
OH
StAn
Sn1
Overheat Protection (Spa is deactivated)
DO NOT ENTER THE WATER. If the spa water has reached 112 F, remove
the spa cover to cool the water. Overheating may occur if the filter cycle
is set too long. At 110 F, the spa should reset itself. If the high limit sensor
detects 118 F at the heater, the spa will shut down. When the heater
cools to 110 F, press any button to reset the spa. If the spa will not
reset, then shut off power to the spa and call your dealer or service
organization.
The spa is in standard mode and will continually heat to the set
temperature.
Standard
EcoN
The spa is in economy mode. ECON is flashed alternately with
COOL and the current spa temperature and when the spa water is
more than 20 F cooler than the set temperature. The circulation
pump and heater will operate to warm the water to within 15 F of
the set temperature.
Economy
FLO
Flashing alternately with temperature. The filter may need cleaning.
The water level is too low. Be sure flow valves are open. Bleed
Circulation Pump if needed. FLO (NOT FLASHING) a pressure
switch has malfunctioned. Contact your dealer or service organization.
Flow
COOL
The spa water is more than 20 F cooler than the temperature last
set. No action is required. Spa is functioning properly. The circulation
pump and heater will operate to warm the water to within 15 F of the
set temperature.
Cool
The high-limit sensor or water temperature sensor is not working. Call
your dealer or service organization.
Sensor 1(Spa is deactivated)
Sn3
The main sensor is not working. Call your dealer or service organization.
Sensor 3(Spa is deactivated)
Diagnostic Messages
ice
Ice
Top Side Control Instructions
18