Dynasty Spas Elite System D-3000 Hot Tub User Manual


 
Your spa will automatically filter itself twice each day. The first filter
cycle will begin 1 minute after the spa is energized. The second filter cycle
will begin 12 hours after the start of the first filter cycle. Filter duration
is programmable at the topside panel for 0, 1, 2, 3, 4 or 12 hours. The
default filter time is 2 hours. To program, press the or pad,
then the pad. Continue to press the or pad to select
the filter duration. Press the pad again to exit programming. The
low speed of pump 1 constantly runs during the filter times (unless the
high speed is on). The ozone generator (if installed) will run 24 hours
a day.
OH
FL
Sn
Overheat Protection (Spa is deactivated)
If the high limit sensor detects 40 F at the heater, then the high speed
of pump 1 and pump 2 (if installed) automatically activates to provide
freeze protection. The equipment stays on until the sensor detects
45 F at the heater. Freeze protection is activated regardless of the spa's
status. In colder climates, an optional additional freeze sensor may be
added to protect against freeze conditions. See your dealer for details.
DO NOT ENTER THE WATER. If the spa water has reached 112 F, remove
the spa cover to cool the water. Overheating may occur if the filter cycle
is set too long. At 110 F, the spa should reset itself. If the high limit sensor
detects 118 F at the heater, the spa will shut down. When the heater
cools to 110 F, press any button to reset the spa. If the spa will not
reset, then shut off power to the spa and call your dealer or service
organization.
Flow Switch Detection
The high-limit sensor or water temperature sensor is not working. Call
your dealer or service organization.
Sensor (Spa is deactivated)
WARNING! SHOCK HAZARD! No User Serviceable Parts.
Do not attempt service of this control. Contact you dealer or service
organization for assistance. Follow all owner's manual power connection
instructions. Installation must be performed by a licensed electrician and
all grounding connections must be properly installed.
Preset Filter Cycles
Freeze Protection
Diagnostic Messages
Top Side Control Instructions
Flashing alternately with temperature. The filter may need cleaning.
The water level is too low. Be sure flow valves are open. FL (NOT
FLASHING) a pressure switch has malfunctioned. Contact your dealer
or service organization.
13