Dynasty Spas Elite System D-3000 Hot Tub User Manual


 
1 minute after the spa is energized. The second filter cycle will begin
12 hours after the start of the first filter cycle. Filter duration is programm-
able at the topside panel for 0, 1, 2, 3, 4 or 12 hours. To program, press
the SET pad, then the JETS pad. Press the SET pad again and F2 will be
displayed on the panel. (F2 is the default filter time and indicates a 2 hour
cycle). Continue pressing SET to cycle through the rest of the filter time
options, FO =O hour, F1 = 1 hour, F2 = 2 hours, F3 = 3 hours, F4 = 4 hours,
and FC = 12 hours. Press the JETS pad again to exit the programming mode.
During filtration, the low-speed pump will run and the blower (if installed)
operates for 30 seconds at the start of the first filter cycle to clean out
the air channel. If a circulation pump is installed, when the water is at set
temperature or below, it will run for 24 hours/day to constantly filter
the water. However, it turns off at 2 F above the set temperature and comes
back on for 1 hour every 3 hours until set temperature is reached again.
An ozone generator (if installed) also runs 24 hours/day.
OH
FL
Sn
Overheat Protection (Spa is deactivated)
If the high limit sensor detects 40 F at the heater, then the high speed
of pump 1 and pump 2 (if installed) automatically activates to provide
freeze protection. The equipment stays activated until the sensor detects
45 F at the heater. Freeze protection is activated regardless of the spa's
status. In colder climates, an optional additional freeze sensor may be
added to protect against freeze conditions. See your dealer for details.
DO NOT ENTER THE WATER. If the spa water has reached 112 F, remove
the spa cover to cool the water. Overheating may occur if the filter cycle
is set too long. At 110 F, the spa should reset itself. If the high limit sensor
detects 118 F at the heater, the spa will shut down. When the heater
cools to 110 F, press any button to reset the spa. If the spa will not
reset, then shut off power to the spa and call your dealer or service
organization.
Flow Switch Detection
The high-limit sensor or water temperature sensor is not working. Call
your dealer or service organization.
Sensor (Spa is deactivated)
Preset Filter Cycles (cont.)
Freeze Protection
Diagnostic Messages
The jets and blower (if installed) can also be activated from an
auxiliary panel. The operation is the same as described for the main
panel.
Auxiliary Panel (optional)
Top Side Control Instructions
Flashing alternately with temperature. The filter may need cleaning.
The water level is too low. Be sure flow valves are open. FLO (NOT
FLASHING) a pressure switch has malfunctioned. Contact your dealer
or service organization.
15