Dimension One Spas Dream HP Hot Tub User Manual


 
2002 @ Home Hot Tubs
Owner’s Manual
3. Locate the owner’s packet inside in equipment compartment (plastic bag with parts and
manual). Inside the bag is a plastic hose bib.
4. Screw the hose bib onto the male fitting located at the bottom of
the hot tub on the pedestal, to the lower right of the equipment
compartment.
5. Close the valve on the side of the hose bib and screw the cap onto
the end of the hose bib.
6. Check the pump unions to be sure that they are tight to prevent the possibility of leakage in the equipment
compartment
.
7. Fill your spa with water up to 6"(15.24 cm) below the lip of the spa.
8. Turn on the circuit breaker. One minute after the power is turned on, the spa will automatically begin its first,
one hour filtration cycle. Let the system run for 30 to 45 seconds to prime the pump. On two pump models,
Pump 2 will operate on high speed for the first minute of each filter cycle. If there is no jet action, then the
water level is too low or there is air trapped in the plumbing lines. To eliminate the trapped air, turn off the
pump(s) and loosen the top pump union slightly to let the air escape. Re-tighten the pump union and turn on
the pump again.
9. Your spa will automatically filter itself twice each day. At the beginning of each filtration cycle, the pump will
run on high speed for 5 minutes and then on low-speed for the remainder of the filter cycle. The second
filtration cycle will begin twelve hours after the start of the first. To reset the start of these cycles, simply turn
off power to the spa by opening the circuit breaker box, turn the breaker off, and then turn it back on. This
resets the filtration cycle to start one minute later. Or follow the procedure outlined in “Number of Filter
Cycles" and “Filter Cycle Duration”. The filter cycle LED indicator will be on when there is a filter cycle is
running.
10. A thermostat controls the spa temperature. Whenever there is a call for heat, your spa will turn on the
heater and the pump will run at low speed as necessary to maintain the temperature. Push the UP pad until
the desired temperature is indicated on the display screen. In a few seconds, the screen will start displaying
the current spa water temperature again. The maximum temperature that can be set is 104°F (40° C). Heating
will occur at the rate of 1 (0.55°C to 8° F (4.4° C) per hour.
13