DeVillbiss Air Power Company D26968 Portable Generator User Manual


 
16- ENG
D26968
Note 1: Change oil after first two (2) operating hours and every 50 operating
hours thereafter, more often if operated in extreme dusty or dirty conditions.
Note 2: Check oil after 5 hours of operation.
CUSTOMER RESPONSIBILITIES TABLE
MAINTENANCE TASK
Before
each
use
Every 25
Hours of
Every
Season
Every 50
Hours of
Every
Season
Every 100
Hours of
Every
Season
Check Spark Plug
Prepare unit for storage if it is to remain
idle for more than 30 days.
MAINTENANCE
Check oil level
Change oil
Clean Air Filter Assembly
Prepare Unit for Storage
See Note 2
X
See Note 1
X
X
X
GENERAL RECOMMENDATIONS
The warranty of the generator does not cover items that have been subjected to
operator abuse or negligence. To receive full value from the warranty, operator
must maintain the generator as instructed in this manual.
ENGINE MAINTENANCE
Refer to the Engine Operator's manual for service and maintenance of the
engine.
4. Voltage sensitive equipment should be the last equipment connected to the
generator. Plug voltage sensitive appliances such at TV's, VCR's, micro-
waves, ovens, computers, and cordless telephones into a UL listed voltage
surge protector, then connect the UL listed voltage surge protector to the
generator.
Failure to connect and operate equipment in this sequence
can cause damage to equipment and will void the warranty
on your generator.
Follow the wattage calculation table in the Wattage Calculation section of
this manual. Overloading the generator will cause power fluctuations and
can damage equipment and appliances.
DeVilbiss Air Power Company will only be responsible for damage to
customer's equipment when the generator is determined to be defective.
This determination will only be made by an authorized representative of
DeVilbiss Air Power Company and this decision will be final. DeVilbiss Air
Power Company reserves the right to inspect the electrical connections at
the customer's site of operation and test the generator for proper opera-
tion before any determination of liability is made. Failure to maintain the
equipment or wiring for inspection will void any claim for damages by the
customer. DeVilbiss Air Power Company will not be responsible for
equipment damaged as a result of voltage surges, improper operation or
improper installation of the generator.