Desa SPC-54PHW, SPC-54PHB, SPC-54PHT, SPC-54PHS Patio Heater User Manual


 
www.desatech.com
114144-01E
3
This is a propane, direct-fired heater. Propane is
heavier than air. If propane leaks from a connection
or fitting, it sinks to the floor, collecting there with
the surrounding air, forming a potentially explosive
mixture. Obviously, propane leaks should be avoided,
so set up the propane supply with utmost care. Read
Propane/LP Safety, page 4 for additional informa
-
tion about detecting propane leaks. Leak check new
connections or reconnections with a soap and water
solution and follow all connection instructions herein.
Also, ask your propane dealer for advice on the
propane application and supply installation and ask
them to check it if there are any questions.
When the heater is to be operated in the presence of
other people the user is responsible for properly ac
-
quainting those present with the safety precautions
and instructions, and of the hazards involved.
Make certain you read and understand all warn
-
ings. Keep this manual for reference. It is your
guide to safe and proper operation of this heater.
1. Check the heater thoroughly for damage. DO
NOT operate a damaged heater.
2. DO NOT modify the heater or operate a heater
which has been modified from its original
condition.
3. Use only propane/LP gas.
4. Use only VAPOR WITHDRAWAL propane
supply. The propane cylinder must be arranged
for vapor-withdrawal, in accordance with the
Compress Gas Associations, Small Propane
Bottle Assembly. If there is any question about
vapor withdrawal, ask your propane dealer.
5. Never use the heater if the ballast weight is
not assembled onto the base. The base must
be weighted to avoid tipping.
6. Use only the hose and regulator assembly
provided with the heater.
7. Inspect hose assembly before each use of the
heater. If there is excessive abrasion or wear,
or hose is cut, replace with hose assembly
listed on parts list before using heater.
8. This heater is for OUTDOOR USE ONLY,
even so, make sure that there is ample fresh air
ventilation. Do not use in buildings, garages
or other enclosed spaces.
9. If at any time gas odor is detected, IMMEDI
-
ATELY DISCONTINUE operation until the
source of gas has been located and corrected.
Read Propane/LP Safety, page 4 for additional
information about detecting propane leaks.
SAFETY INFORMATION
Continued
10. Install the heater such that it is not directly
exposed to water spray, rain and/or dripping
water.
11. Maintain minimum clearance to people or
normal combustible material (like paper) of
3.6 ft. (1100 mm) from top and 2 ft. (609 mm)
from the reflector.
12. Operate only on a stable, level surface.
13. Do not spray aerosols near the heater during
use or shortly thereafter.
14. Do not clean heater with combustible or cor
-
rosive cleaners. Use warm, soapy water.
15. Check control compartment burners and cir
-
culation air passageways for free air passage,
make sure that there are no obstructions. These
areas are a common location for spider webs,
which can present a dangerous condition,
damage the heater and render it unsafe for
use. The heater must be checked if any of the
following conditions exist:
a) Gas smell along with predominate yellow
tipping of the burner.
b) Heater does not reach temperature.
c) Uneven burner glow.
d) Burner makes popping noises during nor
-
mal use, other than during shutdown.
16. Use only soapy water (1 part liquid dishwash
-
ing detergent to 3 parts water) to conduct
leak tests whenever a propane cylinder is
connected. Bubbles indicate a leak.
17. Do not adjust gas regulator. If you are unsure
of your appliances gas type or pressure, call
a qualified service person.
18. Place the control knob on "OFF" position
when heater is not in use.
19. Always disconnect the gas supply after the
heater is turned "OFF".
20. Do not move, handle or service while hot or
burning.
21. Allow 45 minutes to cool down after use
before attempting to move heater.
22. Do not operate this appliance in windy con
-
ditions. Maximum allowable wind speed is
10 mph (16 Km/h).
23. Do not operate this appliance in temperature
conditions below 40° F (5° C).
24. Keep heater away from areas where flammable
liquids, vapors or solids are stored or used.
25. If operated in salt air environments, the
unit will require more frequent cleaning;
otherwise, the longevity of the unit will
deteriorate rapidly. Use warm soapy water to
clean the unit.