Craftsman 919.67937 Portable Generator User Manual


 
READ AND UNDERSTAND ALL WARNINGS BEFORE
ATTEMPTBNG TO OPERATE GENERATOR°
HAZARD
Lifting a very heavy object.
RiSK FROM LiFTiNG
WHAT COULD HAPPEN
Serious injury can result from attempt-
ing to lift too heavy an object.
HOW TO PREVENT iT
The generator istoo heavy to be lifted
by one person. Obtain assistance
from others before you try to move
it.
Read Owner's Manual Do not operate equipment unflHyou have read Owner's ManuaHfor
Safety, _ and Maintenance Instructions,
This product is not equipped with a spark arresting muffHer.If the product will be used around flammable materials, or on
land covered with materials such as agricultural crops, forest, brush, grass, or other similar items, then an approved spark
attester must be installed and is legally required in the state of California. it is a violation of California statutes section
130050 and/or sections 4442 and 4443 of the California Public Resources Code, unless the engine is equipped with a spark
arrestor, as defined in section 4442, and maintained in effective working order. Spark arrestors are also required on some
U.S. Forest Service land and may also be legally required under other statutes and ordinances.
Engine exhaust contains chemicals known, in certain quantities, to cause cancer, birth defects or other reproductive harm.
CARTON CONTENTS
Main Unit
Owner's Manual
Battery Charge Cables
Main Generator Unit
OwnerBs ManuaJ
Battery Charge Cables
CAUTION: Read owner's manual. Do not attemptto
operate equipment until you have read Owner's
Manual for Safety, Operation, and Maintenance In-
structions.
REMOVE GENERATOR FROM CARTON
Open carton from top.
Cut carton along dotted lines.
Remove all carton inserts.
Remove generator through opening in carton.
GROUNDBNG THE GENERATOR
This generator should be grounded to help prevent
accidental electrical shock. Shown below is a picture of
the grounding lug supplied on your generator. First, drive
a 3/4" or 1" diameter copper pipe or rod into the ground
close to the generator set. The pipe must penetrate moist
earth. Using #10 gauge wire, connect one end of the wire
into the grounding lug. Next, connect the other end of the
wire to the copper pipe or rod using an approved ground
clamp.
I}
iMPORTANT: Before any attempt to start your generator
be sure to check engine oil (See OPERATION under
Engine Oil on page 11)
Grounding Lug
8 -- ENG