Chicago Electric 90282 Utility Vehicle User Manual


 
Page 2SKU 90282
Specifications
ITEM DESCRIPTION
Capacity 2,000 lbs.
Cable 49 feet (L) x 5/32 inches (dia.)
Drum Size 1-1/4 (dia.) x 2-7/8 (L) inches
Hook 4 (L) x 5/8 inch opening; spring loaded latch
Base Plate Size
5-1/4 (L) x 4 (W) x 4-1/4 (H) inches;
2 mounting holes: 5/16 (dia.) inch
Motor Power 12 VDC
Gear Reduction Ratio 153:1
Cable Speed
10.5 feet per minute (500 lb. load); 10 amp
7.5 feet per minute (1000 lb. load); 40 amps
5.9 feet per minute (1500 lb. load); 60 amps
4.2 feet per minute (2000 lb. load); 90 amps
Control Cable
8-1/2 feet, handheld pistol grip with pushbutton
switches marked IN and OUT
Clutch Free-spooling pull-out clutch release
Overall Dimensions 11-3/8 (L) x 4-1/2 (D) x 4-1/4 (H) inches
Power Cables
Switch-to-motor: 51" (L) feet with lugs
Switch-to-battery: 68" (L) feet with lugs
Weight 13.9 lbs.
Save This Manual
You will need the manual for the safety warnings and precautions, assembly instructions,
operating and maintenance procedures, parts list and diagram. Keep your invoice with this
manual. Write the invoice number on the inside of the front cover. Keep the manual and
invoice in a safe and dry place for future reference.
Safety Warnings and Precautions
WARNING: When using tool, basic safety precautions should always be followed to
reduce the risk of personal injury and damage to equipment.
Read all instructions before using this tool!
1. Keep work area clean. Cluttered areas invite injuries.
2. Observe work area conditions. Do not use machines or power tools in damp or wet
locations. Don’t expose to rain. Keep work area well lighted. Do not use electrically
powered tools in the presence of flammable gases or liquids.
, Amperage at Maximum Load = 100
- #12 AWG
with lugs
with lugs
REV 04/04