Chauvet E-190WW Landscape Lighting User Manual


 
Setup
-6- OVATION™ E-190WW User Manual Rev. 3
3. Setup
AC Power
Each OVATION™ E-190WW has an auto-ranging power supply that works with an input
voltage range of 100~240 VAC, 50/60 Hz. To determine the power requirements for
each OVATION™ E-190WW
, refer to the label affixed to the product. You can also refer
to the Technical Specifications chart in this manual.
The listed current rating indicates the maximum current draw during normal operation.
For more information, you may download Sizing Circuit Breakers from the CHAUVET
®
website www.chauvetpro.com.
Always connect this product to a protected circuit with an appropriate electrical
ground to avoid the risk of electrocution or fire.
Never connect this product to a rheostat (variable resistor) or dimmer circuit, even
if the rheostat or dimmer channel serves only as a 0 to 100% switch.
AC Plug
The OVATION™ E-190WW comes with a power input cord terminated with a Neutrik®
powerCON® A connector on one end and an Edison plug on the other e
nd (U.S. market).
If the power input cord that came with your product has no plug, or if you need to change
the Edison plug, use the table below to wire the new plug to the power input cord.
Connection Wire (U.S.) Wire (Europe) Screw Color
AC Live
Black
Brown
Yellow or Brass
AC Neutral
White
Blue
Silver
AC Ground
Green/Yellow
Green/Yellow
Green
Fuse Replacement
Make sure to disconnect the product’s power cord before replacing a blown fuse.
1. Disconnect this product from power.
2. Using a Phillips #2 head screwdriver, unscrew the fuse holder
cap from the housing.
3. Remove the blown fuse and replace with another fuse of the
same type and rating (T 3.15 A, 250 V).
4. Screw the fuse holder cap back in place and reconnect power.
Always replace the blown fuse with another of the same type and rating.