CU300
CU400
Standard electrical rating two power
source: One for heater and one for light
Optional Options Electrical Ratings
Service 1
Heater ratings CD player ratings
Phase 1 Phase 1
Voltage 240 VAC Voltage 120 VAC
Amperage 33.3 amps Amperage 3 amps
Wire size 8-2 W/G Wire size 14-3 W/G
Service 2
Vapor proof light LED lighting
Phase 1 Phase 1
Voltage 120 VAC Voltage 120 VAC
Amperage 1 amp Amperage 1
Wire size 14-2 W/G Wire size 14-3 W/G
OD100
OD200
Standard electrical rating two power
source: One for heater and one for light
Optional Options Electrical Ratings
Service 1
Heater ratings CD player ratings
Phase 1 Phase 1
Voltage 240 VAC Voltage 120 VAC
Amperage 21.6 amps Amperage 3 amps
Wire size 10-2 W/G Wire size 14-3 W/G
Service 2
Vapor proof light LED lighting
Phase 1 Phase 1
Voltage 120 VAC Voltage 120 VAC
Amperage 1 amp Amperage 1 amp
Wire size 14-2 W/G Wire size 14-3 W/G
Interior Light
Manufacturer, Exceline
100 Watts light bulb maximum
120 Volts 60 Hz.
cUL and UL listed File E80322
Fixture luminarie Suitable for Wet locations
Type A lamp
Exterior Light
Manufacturer, Hampton Bay
100 Watts light bulb maximum
120 Volts 60 Hz.
UL listed A-178,320
Incandescent luminarie suitable for wet locations