2011 Genesis Portable Spa
LTR20111058, Rev. B
Preparing for Your New Portable Spa
www.calspas.com
4
110V / 60 Hz
This product is a cord-connected spa with a pump
heater, lighting xture, and spa side control. The op-
erating power is 110V AC.
A licensed electrician may be required to upgrade
your standard receptacle and/or circuit breaker. Al-
ways follow applicable local, state and federal codes
and guidelines.
The spa is equipped with a 15 amp GFCI cord and
plug kit.
Plug the spa into a dedicated electrical line with a 15
amp breaker.
Always use a weatherproof-covered receptacle. Re-
ceptacle shall be located not less than 5 feet (1.5
m) from and not exceeding 10 feet (3.0 m) from the
inside wall of the spa (NEC 680.43(A)).
Do not use extension cords. Using an extension cord
will void your warranty.
Do not bury the power cord. If your cord becomes
damaged, replace it before next usage.
If you need to replace your cord, replace it with a
15 amp GFCI connection. The cord may not be lon-
ger than 15 feet (4.6 m). You can order a replace-
ment GFCI and cord kit from Cal Spas, part number
ELE09700086.
Electrical Installation
Testing the GFCI
Test the GFCI plug prior to rst use and periodically
when the spa is powered.
Plug in the GFCI into the power outlet. The indi-1.
cator should turn on.
Press the TEST button. The GFCI will trip, the 1.
indicator will turn off, and the spa will stop op-
erating.
Press the RESET button. The GFCI will reset, the 2.
indicator will turn on again, and the spa will turn
back on.
The spa is now safe to use.
If the GFCI trips while the spa is in use, press the
RESET button. If the GFCI does not reset, unplug the
spa and call your local Cal Spas dealer for service. DO
NOT USE THE SPA!