Cal Spas LTR20111058 Hot Tub User Manual


 
2011 Genesis Portable Spa
LTR20111058, Rev. B
Operating Your Spa
www.calspas.com
11
Diagnostic Messages
Message Meaning Action Required
No message
on display
1) Spa temperature is unknown. 1) After pump has been running for 2 minutes tem-
perature will be displayed.
2) Spa is in Economy or Sleep
mode.
2) In Economy or Sleep mode, the pump may be off
for hours outside a lter cycle. If you wish to see the
current spa temperature, either switch to Standard
mode or turn Jets1 on for at least two minutes.
3) Power has been cut off to the
spa.
3) The control panel will be disabled until power re-
turns. Spa settings and time of day will be preserved
for 30 days with a battery back-up.
dr Insufcient water detected in
heater. Spa will be shut down for
15 minutes.
Check water level in spa. Rell if necessary. Make
sure pumps are been primed and lter cartridges are
clean. Press any button to reset or wait 15 minutes
and spa will automatically reset. If message spa does
not reset, call your dealer or service organization.
drY Insufcient water detected in
heater. Spa is shut down.
(Displays on third occurrence of dr
message.)
Follow directions for dr message and press any button
to reset spa. Spa will not automatically reset when dry
or dY is displayed.
Ec Indicates heater is in Economy
Mode.
None.
-- Temperature unknown After the pump has been running for two minutes, the
temperature will be displayed.
HFL A difference in readings between
temperature sensors has been
detected indicating a possible water
ow problem.
Make sure spa is lled to proper level and that pumps
are primed and lter cartridges are clean. If message
does not reset, call your dealer or service organiza-
tion.
ICE Potential freeze condition detected. No action required. The pumps and the blower will
automatically activate regardless of spa status.
LF Persistent low ow problems.
Heater is shut down, but other spa
functions continue to run normally.
Displays on the fth occurrence of
the HL or HFL message within 24
hours.
Follow action required for HL or HFL message. Heat-
ing capacity of the spa will not reset automatically.
Press any button to reset.
OHS Overheat protection. The spa has
shut down. One of the sensors
has detected that the spa water is
110°F.
DO NOT ENTER THE WATER. Remove the spa cover
and allow water to cool. At 107°F, the spa should
automatically reset. If spa does not reset, shut off
the power to the spa and call your dealer or service
organization.