Buffalo Tools GEN2000LP Portable Generator User Manual


 
GEN2000LP 2000 Surge Watt / 1350 Running Watt Portable LP Generator Manual
15
Ground this generator by tightening the grounding nut against a grounding wire as previously illustrated in Figure 3. A generally acceptable
grounding wire is a No. 12 AWG (American Wire Gauge) stranded copper wire. The other end of this grounding wire should be connected to a
copper or brass grounding rod that is driven into the earth. Grounding codes can vary by location. Contact a local electrician for information on
grounding regulations for your area.
STARTING THE GENERATOR
STOP!
Before starting this generator, confirm that all the steps in the section titled, “Preparing the Generator for Use,” of this manual have been
correctly completed. If unsure about how to perform any of these steps, call 1-866-460-9436, Monday - Friday, 8 AM - 4 PM Central Time for
customer service.
Disconnect all electrical loads from this generator before attempting to start.
Step 1 Open fuel supply source.
Step 2 Turn ENGINE SWITCH at ON position.
Step 3 Move Choke Lever to CHOKE position.
Step 4 For recoil start: Pull the STARTER GRIP slowly until resistance is felt and then pull rapidly. After the engine started, return the STARTER
GRIP gently to prevent damage to the starter or housing. DO NOT allow the starter grip to snap back. Return it slowly by hand.
Step 5 Turn the CHOKE LEVER to RUN position
Choke Rod
The choke is used to provide an enriched fuel mixture when starting a cold engine. It can be opened and closed by operating the choke rod
manually. Pull the rod out toward CLOSED to enrich the mixture for cold starting
Step 03