General Recommendations
Regular maintenance will improve the performance and
extend the life of the generator. See any authorized Briggs
& Stratton dealer for service.
The generator’s warranty does not cover items that have
been subjected to operator abuse or negligence. To
receive full value from the warranty, the operator must
maintain the generator as instructed in this manual.
Some adjustments will need to be made periodically to
properly maintain your generator.
All service and adjustments should be made at least once
each season. Follow the requirements in the Maintenance
Schedule chart above.
NOTE: Once a year you should clean or replace the
spark plug and replace the air filter. A new spark plug and
clean air filter assure proper fuel-air mixture and help your
engine run better and last longer.
Emissions Control
Maintenance, replacement, or repair of the emissions
control devices and systems may be performed by any
non-road engine repair establishment or individual. See
Emissions Control System Warranty in the Warranties section.
Maintenance
Maintenance Schedule
Follow the hourly or calendar intervals, whichever occurs first. More frequent service is required when operating in
adverse conditions noted below.
¹ Change oil after the first (5) operating hours and every 50 hours or every year, whichever occurs first, thereafter.
Change oil sooner when operating under dirty or dusty conditions.
² Replace more often under dirty or dusty conditions.
Maintenance Schedule - Fill in Dates as You Complete Regular Service
Service Dates Service Dates
Maintenance Task
Before Each
Use
Every 25 Hours
or Yearly
Every 50 Hours
or Yearly
Every 100 Hours
or Yearly
Clean debris
X
Check oil level
X
Change engine oil
Service air cleaner
Service spark plug
X
Service spark arrester
X
Clean cooling system
Check valve clearance
X
Prepare for storage
If unit is to remain idle for longer than 30 days.