Baldor MN2410 Portable Generator User Manual


 
Appendix D
Premier OHV100E Series
Premier OHV100E Series D-1MN2410
Information in this Appendix applies to the OHV100E Baldor Generator.
Caution: The brass connecting tab on some 120VAC duplex receptacles have been removed. Each
receptacle is powered by a separate generator winding. When replacing a receptacle, inspect
the brass tab that normally links both receptacles. If it is removed, be sure to remove the
brass tab from the replacement receptacle before it is installed. Failure to remove the tab will
cause a direct short to the generator windings and cause possible generator damage.
Operator Panel Configuration
Figure D-1 OHV100E Operator Panel
Auto Idler Switch.
ON - Auto idler is active, engine RPM will reduce when load is removed.
OFF - Engine runs at fixed speed (set by governor).
Elapsed Time.
Displays the total run time hours of the generator set.
AC Voltmeter.
This voltmeter displays the voltage level being produced by the generator set.
AC Circuit Breakers.
Provide overload protection for the generator set.
120 Volts NEMA 5-20R GFCI Receptacle.
This ground fault circuit interrupter duplex receptacle is rated at 125VAC, 20 Amps.
30 AMPS 120 Volts NEMA L5-30R Receptacle.
Twist-lock style receptacle rated for 125VAC, 30 Amps.
30 AMPS 120/240 Volts NEMA L14-30R Receptacle.
Twist-lock style receptacle rated for 125/250VAC, 30 Amps.
50 AMPS 120/240 Volts CS6369 Receptacle.
Twist-lock style receptacle rated for 125/250VAC, 50 Amps.
AC
VOLTMETER
AUTO IDLER
OFF
ON
AC CIRCUIT
BREAKERS
120 VOLTS
30 AMPS
120 VOLTS
30 AMPS
120/240 VOLTS
ELAPSED
TIME
NEMA
L5-30R
120 VOLTS
NEMA
L14-30R
50 AMPS
120/240 VOLTS