Baldor MN2410 Portable Generator User Manual


 
Appendix C
Premier OHV Series
Premier OHV Series C-1MN2410
Information in this Appendix applies to the following Baldor Generators:
OHV30, OHV50, OHV60, OHV60E, OHV85E
Caution: The brass connecting tab on some 120VAC duplex receptacles have been removed. Each
receptacle is powered by a separate generator winding. When replacing a receptacle, inspect
the brass tab that normally links both receptacles. If it is removed, be sure to remove the
brass tab from the replacement receptacle before it is installed. Failure to remove the tab will
cause a direct short to the generator windings and cause possible generator damage.
Operator Panel Configuration
Figure C-1 OHV30 Operator Panel
120 VOLTS
AC CIRCUIT BREAKER
NEMA 5-20R GFCI Receptacle.
This ground fault circuit interrupter duplex receptacle is rated at 125VAC, 20 Amps.
Standard Duplex Receptacle. Standard household receptacle rated for 125VAC, 30 Amp
When using this receptacle, ground fault protection is provided by the GFCI receptacle
.
Hour Meter.
Displays the total run time hours of the generator set.
Circuit Breaker.
Provide overload protection for the generator set.
ELAPSED
TIME
120 VOLTS
Figure C-2 OHV40/OHV50/OHV60/OHV60E Operator Panel
Circuit Breaker.
Provide overload protection for the generator set.
120 Volts NEMA 5-20R GFCI Receptacle.
This ground fault circuit interrupter duplex receptacle is rated at 125VAC, 20 Amps.
120 Volts NEMA L5-30R Receptacle.
Twist-lock style receptacle rated for 125VAC, 30 Amps.
120/240 Volts NEMA L14-30R Receptacle.
Twist-lock style receptacle rated for 125/250VAC, 30 Amps.
AC
VOLTMETER
AUTO IDLER
OFF
ON
CIRCUIT
BREAKER
15 AMPS
120 VOLTS
30AMPS
120 VOLTS
ELAPSED
TIME
CIRCUIT
BREAKER
15 AMPS
120VOLTS
30AMPS
120/240VOLTS
AC Voltmeter. This voltmeter displays the voltage level being produced by the generator set.
Elapsed Time. Displays the total run time hours of the generator set.
Auto Idler Switch. ON - Auto idler is active, engine RPM will reduce when load is removed. OFF - Engine runs at fixed speed (set by governor).
Figure C-3 OHV85E Operator Panel
Auto Idler Switch.
ON - Auto idler is active, engine RPM will reduce when load is removed.
OFF - Engine runs at fixed speed (set by governor).
DC ON - Auto Idler is Off and DC output terminals have power for 12V loads.
Elapsed Time.
Displays the total run time hours of the generator set.
AC Voltmeter.
This voltmeter displays the voltage level being produced by the generator set.
AC Circuit Breakers.
Provide overload protection for the generator set.
120 Volts NEMA 5-20R GFCI Receptacle.
This ground fault circuit interrupter duplex receptacle is rated at 125VAC, 15 Amps.
120 Volts NEMA L5-30R Receptacle.
Twist-lock style receptacle rated for 125VAC, 30 Amps.
120/240 Volts NEMA L14-30R Receptacle.
Twist-lock style receptacle rated for 125/250VAC, 30 Amps.
AC
VOLTMETER
AUTO IDLER
DC
ON
AC CIRCUIT
BREAKERS
120 VOLTS
120 VOLTS
120/240 VOLTS
120 VOLTS
ELAPSED
TIME