Appendix B
Premier R Series
Premier R Series B-1MN2410
Information in this Appendix applies to the following Baldor Generators:
R30, R45, R45E, R60, R60E
Caution: The brass connecting tab on some 120VAC duplex receptacles have been removed. Each
receptacle is powered by a separate generator winding. When replacing a receptacle, inspect
the brass tab that normally links both receptacles. If it is removed, be sure to remove the
brass tab from the replacement receptacle before it is installed. Failure to remove the tab will
cause a direct short to the generator windings and cause possible generator damage.
Operator Panel Configuration
Figure B-1 R30 Operator Panel
120 VOLTS
AUTO IDLER
AC CIRCUIT BREAKER
OFF
ON
NEMA 5-15R GFCI Receptacle.
This ground fault circuit interrupter duplex receptacle is rated at 125VAC, 15 Amps.
Standard Duplex Receptacle. Standard household receptacle rated for 125VAC, 30
Amps.
When using this receptacle, ground fault protection is provided by the GFCI recepta
c
Hour Meter.
Displays the total run time hours of the generator set.
Auto Idler Switch.
ON - Auto idler is active, engine RPM will reduce when load is removed.
OFF - Engine runs at fixed speed (set by governor).
Circuit Breaker.
Provide overload protection for the generator set.
ELAPSED TIME
120 VOLTS
PUSH TO RESET
Figure B-2 R45/R45E/R60/R60E Operator Panel
Auto Idler Switch.
ON - Auto idler is active, engine RPM will reduce when load is removed.
OFF - Engine runs at fixed speed (set by governor).
Elapsed Time.
Displays the total run time hours of the generator set.
AC Voltmeter.
This voltmeter displays the voltage level being produced by the generator set.
AC Circuit Breakers.
Provide overload protection for the generator set.
120 Volts NEMA 5-15R GFCI Receptacle.
This ground fault circuit interrupter duplex receptacle is rated at 125VAC, 15 Amps.
120 Volts NEMA L5-30R Receptacle.
Twist-lock style receptacle rated for 125VAC, 30 Amps.
120/240 Volts NEMA L14-30R Receptacle.
Twist-lock style receptacle rated for 125/250VAC, 30 Amps.
AC
VOLTMETER
AUTO IDLER
DC
ON
AC CIRCUIT
BREAKERS
120 VOLTS
120 VOLTS
120/240 VOLTS
120 VOLTS
ELAPSED
TIME