Baldor MN2410 Portable Generator User Manual


 
Appendix A
Premier K Series
Premier K Series A-1MN2410
Information in this Appendix applies to the following Baldor Generators:
K3000, K5000, K5000E, K6500, K6500E
Caution: The brass connecting tab on some 120VAC duplex receptacles have been removed. Each
receptacle is powered by a separate generator winding. When replacing a receptacle, inspect
the brass tab that normally links both receptacles. If it is removed, be sure to remove the
brass tab from the replacement receptacle before it is installed. Failure to remove the tab will
cause a direct short to the generator windings and cause possible generator damage.
Operator Panel Configuration
Figure A-1 K3000 Operator Panel
120 VOLTS
120 VOLTS
AC VOLTMETER DC POWER CIRCUIT BREAKERS
DC
OUTPUT
OFF
ON
NEMA 5-15R GFCI Receptacle.
This ground fault circuit interrupter duplex receptacle is rated at 125VAC, 15 Amps.
NEMA L5-30R Receptacle. Twist-lock style receptacle rated for 125VAC, 30 Amps.
DC Output.
12VDC output terminals for 12V loads.
AC Voltmeter.
This voltmeter displays the voltage level being produced by the generator set.
DC Power
Turns On/Off DC power at the DC Output terminals.
Hour Meter.
Displays the total run time hours of the generator set.
Circuit Breakers.
Provide overload protection for the generator set.
Figure A-2 K5000/K5000E/K6500/K6500E Operator Panel
NEMA 5-15R GFCI Receptacle.
This ground fault circuit interrupter duplex receptacle is rated at 125VAC, 15 Amps.
NEMA L5-30R Receptacle. Twist-lock style receptacle rated for 125VAC, 30 Amps.
NEMA L14-30R Receptacle. Twist-lock style receptacle rated for 125/250VAC, 30 Am
DC Output.
12VDC output terminals for 12V loads.
AC Voltmeter.
This voltmeter displays the voltage level being produced by the generator set.
Auto Idler Switch.
ON - Auto idler is active, engine RPM will reduce when load is removed.
OFF - Engine runs at fixed speed (set by governor).
DC ON - Auto Idler is Off and DC output terminals have power for 12V loads.
Hour Meter.
Displays the total run time hours of the generator set.
Circuit Breakers.
Provide overload protection for the generator set.
120 VOLTS
120 VOLTS
AC VOLTMETER AUTO IDLER CIRCUIT BREAKERS
DC
OUTPUT
DC
ON
120/240 VOLTS
OFF