A SERVICE OF

logo

Instructions for the Installer
11
3.2 Burner and Nozzle Data Tables (50-60 cm Models)
Burner
Rated
heat
capacity
(kW)
BOTTLED GAS – G30/G31 30/37 mbar
Nozzle
diameter
1/100 mm
By-pass
mm
1/100
Reduced heat
capacity
(W)
Flow-rate
g/h G30
Flow-rate
g/h G31
Auxiliary
1.0 50 30 350 73 71
Semi-rapid
1.75 65 33 450 127 125
Rapid (3)
3.0 85 45 800 218 214
Rapid (5)
2.3 75 45 800 167 164
Triple Flame
3.2 91 65 1500 233 229
Oven
3.2 87 48 850 233 229
Grill
3.0 87 // // 218 214
Burner
Rated
heat
capacity
(kW)
TOWN GAS – G110 8 mbar
Nozzle
Diameter 1/100 mm
Reduced heat capacity
(W)
Auxiliary
1.0 145 350
Semi-rapid
1.75 185 450
Rapid (3)
3.0 260 800
Rapid (5)
2.3 220 800
Triple Flame
3.3 290 1200
Oven
3.2 270 850
The data for town gas refer to category III 1a2H3+ appliances.
Burner
Rated
heat
capacity
(kW)
NATURAL GAS - G20 20 mbar
Nozzle
Diameter 1/100 mm
Reduced heat capacity
(W)
Auxiliary
1.0 72 350
Semi-rapid
1.75 97 450
Rapid (3)
3.0 115 800
Rapid (5)
2.3 103 800
Triple Flame
3.5 133 1500
Oven
3.2 130 850
Grill
3.0 130 //