A SERVICE OF

logo

Instructions for the Installer
12
3.3 Burner and Nozzle Data Tables (90 cm Models)
Burner
Rated
heat
capacity
(kW)
BOTTLED GAS - G30/G31 30/37 mbar
Nozzle
diameter
1/100 mm
By-pass
mm
1/100
Reduced
heat capacity
(W)
Flow-rate
g/h G30
Flow-rate
g/h G31
Auxiliary 1 50 30 350 73 71
Semi-rapid 1.75 65 33 450 127 125
Rapid 3 85 45 800 218 214
Triple Flame 3.2 91 65 1500 233 229
Fish 1.9 68 45 800 138 136
Oven 3.2 87 48 850 233 229
Maxi oven 5.2 110 59 1200 378 371
Grill 2.9 87 // // 218 214
Maxi grill 4.0 100 // // 291 286
Burner
Rated
heat
capacity
(kW)
TOWN GAS – G110 8 mbar
Nozzle diameter
1/100 mm
Reduced heat capacity
(W)
Auxiliary 1 145 350
Semi-rapid 1.75 190 450
Rapid 3 260 800
Triple Flame 3.5 290 1500
Fish 1.9 190 800
G110 gas cannot be used in models with gas oven.
The data for town gas refer to category III 1a2H3+ appliances.
Burner
Rated
heat
capacity
(kW)
NATURAL GAS - G20 20 mbar
Nozzle diameter
1/100 mm
Reduced heat capacity
(W)
Auxiliary 1 72 350
Semi-rapid 1.75 97 450
Rapid 3 115 800
Triple Flame (4) 3.5 133 1500
Triple Flame (8) 3.5 140 1500
Fish 1.9 94 800
Oven 3.2 130 850
Maxi oven 5.2 164 1200
Grill 2.9 130 //
Maxi grill 4.0 150 //