Chapter A Default Settings VXI/VME-MXI-2
PCI-Based MXI-2 Interface for Windows A-6 ni.com
SMB CLK10 termination (S6) Ignored; effective only when
S7 is set to IN
Polarity of external SMB CLK10
(S3)
Inverted
MXIbus CLK10 signal (S1) Receive CLK10 from MXIbus
MXIbus termination
(U21 Switches 3 and 4)
AutomaticMXIbustermination:
Switch 3 set to OFF; Switch 4
ignored
Configuration EEPROM
(U21 Switches 1 and 2)
User-modifiable; factory
settingsprotected: bothswitches
set to OFF
Table A-10. VME-MXI-2 Hardware Default Settings
Hardware Component Default Setting
A16 base address (U20) Hex C040
VME-MXI-2 intermodule
signaling (W2)
No user-defined pin selected
MXIbus termination
(U21 Switches 3 and 4)
Automatic MXIbustermination:
Switch3OFF;Switch4ignored
Configuration EEPROM
(U21 Switches 1 and 2)
User-modifiable; factory
settingsprotected: bothswitches
OFF
DRAM SIMMs installed Per customer order
SIMM size configuration (S2) OFF if SIMMS are 4 M × 32
or larger; ON if smaller than
4M× 32
Table A-9. VXI-MXI-2/B Hardware Default Settings (Continued)
Hardware Component Default Setting