4. FUNCTION SETTINGS (G50 OPERATION PANEL)
16
Sewing machine motor settings (150-)
No.
Setting
range
Initial
value
Setting
units
Setting details
150 ON/OFF ON -
Slow stop control when treadle is returned to neutral
ON: Slow stop control without step operation
(Low speed operating time before sewing stops is almost constant)
OFF: Above control is not used
(Low speed operating time before sewing stops is not constant)
151 ON/OFF OFF -
Effective hammer operation if needle does not pierce
ON: Effective hammer operation
OFF: No effective hammer operation
152 ON/OFF OFF -
Highest needle position stop operation
ON: Used
OFF: Not used
153
10-500
(ms)
150
(ms)
10
(ms)
Delay time until reverse operation starts during highest needle position stop
operation
* This is only enabled when No. 152 is set to “ON”.
154
-20-20
(degrees)
0
(degrees)
1
Quick reverse needle up stop position setting
* This is only enabled when No. 152 is set to “ON”.
155 0 1 1
Thread wiping operation and presser foot lifting operation during highest
needle position stop operation
* This is only enabled when No. 152 is set to “ON”.
0: The needle is raised, then thread wiping is carried out, and then the
presser foot is lifted
170
5-12
(A)
11
(A)
1
Current limit value during acceleration
* The larger the value, the faster the sewing machine motor acceleration;
the smaller the value, the slower the acceleration. (Setting a small value
may be effective in preventing fluorescent light flickering.)
171
5-12
(A)
10
(A)
1
Current limit value during deceleration
* The larger the value, the faster the sewing machine motor deceleration;
the smaller the value, the slower the deceleration.
172 -3-6 0 1 Gain during high-speed motor operation
173 -3-6 0 1 Gain during low-speed motor operation
174 -3-6 0 1 Weak gain during thread trimming
175 OFF/1 OFF 1
Servo lock operation
OFF: None
1: Servo lock operation occurs when sewing is stopped
176
OFF/
1-120
(seconds)
OFF 1
Servo lock timer setting
* This is disabled when No. 175 is set to “OFF”.
OFF: No timer operation
1-120: Timer operates (1-120 seconds)
177
30-89
(degrees)
45
(degrees)
1
Servo lock release rotation angle [Do not change this setting.]
* This is disabled when No. 175 is set to “OFF”.
2248M
[Do not change this setting.]
[Do not change this setting.]
[Do not change this setting.]
Becomes lower
Becomes higher