A SERVICE OF

logo

S-7000DD
3. USING THE OPERATION PANEL (BASIC OPERATIONS)
12
3. USING THE OPERATION PANEL
(BASIC OPERATIONS)
3-1. Names and functions
The operation panel keys cannot be operated while sewing is in progress.
Select the keys and set the number of stitches before starting sewing.
In the case of keys with indicators, the indicator illuminates when that function is operating, and the indicator switches off
when the key is pressed once more.
Power indicator
0489
D
T
he power indicator illuminates when the power switch is turned on.
(1) Display
When start backtack stitches are being displayed, the indicator of the start backtack key
(4) will illuminate, and the number of A stitches will appear in the A column and the
number of B stitches will appear in the B column.
When end backtack stitches are being displayed, the indicator of the end backtack key
(5) will illuminate, and the number of C stitches will appear in the C column and the
number of D stitches will appear in the D column.
When continuous backtack stitches are displayed, the indicator of the continuous
backtack key (6) will illuminate, and the number of A, B, C and D stitches will appear in
order starting from the left column of the display.
The three indicators on the right side of the window show which value is appearing in
the four columns of the display. The four-column display shows the speed, counter and
stitches. When the stitches are being displayed, the ABCD indicator (10) will illuminate.
(2) SEL (Select) key
The value in the display (1) can be changed each time this switch is pressed.
(3) Setting keys
These keys are used to set the number of backtack stitches for A, B, C and D.
When the key is pressed, the setting increases from 0 up to 9.
If you press the key once more when “9” is displayed, the value will return to “0”.
(4) Start backtack key
When this key is pressed so that the indicator illuminates, the number of start backtack
stitches (0 - 9) in the A and B columns of the display are sewn.
(5) End backtack key
When this key is pressed so that the indicator illuminates, the number of end backtack
stitches (0 - 9) in the C and D columns of the display are sewn. When the treadle is
depressed backward, the end backtack stitches are sewn and then the thread is trimmed
automatically.
If the treadle has not yet been depressed backward, the end backtack function can be set
to ON, the number of stitches can be changed and the function can be set back to OFF.
(6) Continuous backtack key
When this key is pressed so that the indicator illuminates, the number of backtack stitches
(0 - 9) in the A, B, C and D columns of the display are sewn continuously. After the sewing
machine sews a full cycle of stitches set by A, B, C and D, the thread is trimmed
automatically.
0490D
0491D
0492
D
0493
D
0494
D
0495D