10 Specifications
12-Volt DC Section
Internal battery type AGM, sealed lead acid
Internal battery voltage (nominal) 12 Vdc
Internal battery capacity (minimum) 21 Ah
Cycle life at 100% discharge/recharge 170 cycles
cycles at 68°F (20°C)
Maximum load current through 12-volt DC 12 A
Power Socket (breaker protected)
Inverter (115-Volt) AC Section
AC output voltage (nominal) 115 Vac
Maximum continuous AC output power 300 W
Maximum AC surge power 500 W
AC output frequency 60 Hz ± 4 Hz
AC output waveform Modified sine wave
Inverter no-load current (battery drawin with no 0.18 A
load on inverter)
Ambient operating temperature range 32°F - 104°F (0°C - 40°C)
Low battery alarm trigger point 10.7 V (nominal)
Low battery shutdown point 10.0 V (nominal)
Charging System
AC charger bulk charging current 500 mA (maximum)
Bulk charge to float charge transition voltage 14.6 V (nominal)
(peak charging voltage)
Float charge to bulk charge transition voltage 12.9 V (nominal)
(charge restart voltage)
Float charge current (after full charge has terminated) 1 mA (nominal)
Charger Input Socket maximum current 3 A
Specifications subject to change without notice