SPECIFICATIONS
XANTREX PART NUMBERS
AGS System............................................................ 84-2064-00
includes Remote Panel, Controller, and 50' data cable (4/6 conduc-
tor)
INSTALLATION
Mating Connector ...................................... AMP 770583-1
Mating Pins (16) ......................................... AMP 770988-1
Crimping Tool ............................................. AMP 90759-1
The Xantrex AGS Harness (P/N 76-0090-01) includes these
three items.
MECHANICAL
Controller Size: 6.57'' (W) X 4.25'' (H) X 1.875'' (D)
Remote Panel Size: 5.75'' (W) X 3.75'' (H) X 0.93'' (D)
Remote Panel Cutout size: 4.875'' (W) X 2.875'' (H)
Weight: Controller .................................................. 1 lb. 12 oz.
Remote Panel........................................ 3 oz.
ELECTRICAL
Inputs:
Supply voltage.................................................. 9–15.5 VDC
Supply current .................................................. 125 mA DC
2 Thermostats DC
Battery sense.................................................... 9–15.5 VDC
Control Module Outputs:
2 wire Preheat/ Start/ Stop Lines
Remote Port Data cable (proprietary data)
ENVIRONMENTAL
Operating temperature range ................... 0–70 °C
AGS Remote ............................................... Splash proof