United States Stove 6041 Patio Heater User Manual


 
12 USSC
The
Multifuel Heater Model 6041TP/6041HF may be installed as
follows:
1) A freestanding unit
The
Multifuel Heater Model 6041I insert may be installed as
follows:
1) In a pre-fab rebox (Factory Built)
2) In an existing masonry replace
3) As a build-in
MOBILE HOME INSTALLATION REQUIREMENTS
IN ADDITION TO THE STANDARD INSTALLATION INSTRUCTION, THE FOLLOWING
REQUIREMENTS ARE MANDATORY FOR INSTALLATION IN A MOBILE HOME:
WARNING
DO NOT INSTALL IN SLEEPING ROOM
CAUTION
THE STRUCTURAL INTEGRITY OF THE MOBILE HOME FLOOR, WALL AND CEILING/
ROOF MUST BE MAINTAINED.
Check with your local building ofcial as other codes may apply.
INSTALLATION CONFIGURATIONS
1) Heater must be permanently bolted to the oor. Remove the Base Trim and bolt thru the base ange.
2) Heater must have permanent outside air source. (69FAK)
3) Heater must be permanently electrically grounded to the steel chassis of the mobile home.
4) All vertical chimney vent must have wall supports.
5) All exhaust systems must have a spark arrestor.