Troubleshooting
8
Problem Cause Remedy
Engine fails to start Fuel tank empty, or stale fuel.
Blocked fuel line.2.
Choke not in the RUN position.3.
Faulty spark plug.
Key not in ignition switch on engine.5.
Spark plug wire disconnected.
7.
Fill tank with clean, fresh gasoline. Fuel
becomes stale after thirty days.
Clean the fuel line.2.
Move choke control to RUN position3.
Clean, adjust gap or replace.
Insert the key fully into the switch.5.
Connect spark plug wire.
7.
Engine running erratically/
or surging)
Fuel line blocked or stale fuel. 2.
Water or dirt in fuel system.3.
Carburetor out of adjustment.
5.
Move choke control to RUN position.
Clean fuel line and fill tank with fresh clean, 2.
gasoline.
Run engine until it stops. Refill with fresh fuel.3.
Contact an authorized service center.
Contact an authorized service center.5.
Loss of power Spark plug wire loose.
Gas cap vent hole plugged.2.
Connect and tighten spark plug wire.
Remove ice and snow from gas cap. Be 2.
certain vent hole is clear.
Excessive vibration Loose parts or damaged auger. Stop the engine immediately and disconnect
the spark plug wire. Tighten all bolts and
nuts. If vibration continues, have the snow
thrower serviced by an authorized service
dealer.
Snow Thrower fails to
propel itself
Drive control cable in need of adjustment.
Drive belt loose or damaged. 2.
Friction wheel worn.3.
Adjust drive control cable. Refer to
Maintenance & Adjustments Section.
Replace drive belt. Refer to the Service 2.
Section.
Replace the friction wheel.3.
Snow Thrower fails to
discharge snow
Chute assembly clogged.
Shear pin(s) sheared.2.
Foreign object lodged in auger. 3.
Auger control cable in need of adjustment.
Auger belt loose or damaged.5.
Stop engine and disconnect spark plug wire.
Clean chute and inside of auger housing with
clean-out tool or a stick.
Replace shear pin(s).2.
Stop engine immediately and disconnect 3.
spark plug wire. Remove object from auger.
Adjust auger control cable. Refer to the
Maintenance & Adjustments Section.
Refer to Service Section.5.
Chute fails to easily rotate
Chute assembled incorrectly. Unassemble chute control and reassemble as
directed in the Assembly section.