Troy-Bilt 1919 Portable Generator User Manual


 
14
7
Section
Troubleshooting
TROUBLESHOOTING
Problem Cause Solution
No AC output is available,
but engine is running.
1. Circuit breaker is open.
2. Poor connection or defective cord set.
3. Connected device is bad.
4. Fault in generator.
1. Reset circuit breaker.
2. Check and repair.
3. Connect another device that is in
good condition.
4. Contact Authorized Service Facility.
When loads are
connected, engine runs
good but bogs down.
1. Short circuit in a connected load.
2. Generator is overloaded.
3. Engine speed is too slow.
4. Shorted generator circuit.
1. Disconnect shorted electrical load.
2. See "Don't Overload Generator".
3. Contact Authorized Service Facility.
4. Contact Authorized Service Facility.
Engine shuts down during
operation.
Out of gasoline. Fill fuel tank.
Engine lacks power. Load is too high. See "Don't Overload Generator".