Toro TWRS Weather Radio User Manual


 
Dry Out Feature
The Dry Out feature is provided to override the Water Conservation baseline level, allowing the
dry-out delay period to be set in 0.5-day increments from 0.5 to 4.0 days.
Note: Before using the Dry Out feature, allow the sensor system to normalize by cycling through
rain and/or freeze activation several times.
1. Press the Setup button to display Dry Out. The display will indicate the current Dry Out day
setting (factory default is 0.0).
2. Press the Adjust button to select the desired value (0.5 to 4.0 days).
See Figure 24.
Note: Once activated, Dry Out operation can be canceled by pressing the
Smart Bypass button.
Note: Reselecting a Water Conservation level will override the Dry Out feature setting.
Fail Safe Feature
The Fail Safe feature is provided to alert and respond to a loss of communication signal and/or if
the sensor system stays in the active mode for a prolonged period of time. This important feature
safeguards your automatic irrigation system from being inadvertently shut off for an indefinite
period of time due to a sensor system malfunction.
18
Figure 24
RainSensorAlpha7 3/10/2005 3:31 PM Page 18