Topcon GTS-825A Telescope User Manual


 
8-5
8 PARAMETERS SETTING MODE
8.2 Setting Parameters
8.2.1 Parameters for Measurement and Display
[Example setting] S/A BUZZER: OFF, Atmospheric pressure: hPa
Operating procedure Operation Display
1
Press the [F6] key from the main menu icons.
[F6]
2
Press the [F1] (Measurement) key.
[F1]
3
Select the menu by pressing [F6](
) key.
(Example: S/A buzz.))
[F6]
4
Press [F3]() key, and select OFF.
[F3]
5
Select the atmospheric pressure menu by
pressing [F6](
) key.
[F6]
6
Press [F4]() key twice, and select hPa.
[F4]
7
Press [F1](SET) key.
[F1]
8
Press [F5](YES) key. *1)
The display returns main menu.
[F5]
*1) To cancel the setting, press [F6](NO) key.
Parameters
F1 Measurement
F2 Communication
F3 Password
Parameters (Measurement)
Ang.Unit [ deg ] gon mil
Min.Angl OFF [ ON ]
Tilt [ OFF ] 1axis 2axis
SET EXIT <- -> ↑ ↓
Parameters (Measurement)
S/A buzz. OFF [ ON ]
W-corr. OFF [ 0.14 ] 0.20
N/E/Z mem OFF [ ON ]
SET EXIT <- -> ↑ ↓
Parameters (Measurement)
S/A buzz.[ OFF ] ON
W-corr. OFF [ 0.14 ] 0.20
N/E/Z mem OFF [ ON ]
SET EXIT <- -> ↑ ↓
Parameters (Measurement)
Pres.Unit [ mmHg ] inHg hPa
R/L Lock [ OFF ] ON
m/ftLock [ OFF ] ON
SET EXIT <- -> ↑ ↓
Parameters (Measurement)
Pres.Uni mmHg inHg [hPa ]
R/L Lock [ OFF ] ON
m/ftLock [ OFF ] ON
SET EXIT <- -> ↑ ↓
Parameters (Measurement)
> Set OK?
YES NO