Subaru RGX3600 Portable Generator User Manual


 
ENGLISHFRANÇAISEESPAÑOL
-
15
-
NOTE :
When the AC circuit breaker turns off during operation, the generator is over loaded
or the appliance is defective. Stop the generator immediately, check the appliance
and / or generator for overloading or detect and have repaired as necessary by
SUBARU Industrial Power Products dealer or service shop.
To take power out from the TWIST
LOCK RECEPTACLE, insert the
plug into the receptacle, and turn it
clockwise to the lock position.
Be sure to ground the generator if
the connected electrical device is
grounded.
TWIST
Style Ampere Receptacle AC plug Description
up to 20A
NEMA
5-20R
NEMA
5-20P
GFCI (Ground Fault
Circuit Interrupter)
Receptacle,
duplex(REC1)
up to 20A
NEMA
L14-20R
NEMA
L14-20P
Locking
Receptacle(REC2)
up to 30A
NEMA
L5-30R
NEMA
L5-30P
Locking
Receptacle(REC3)
up to 30A
NEMA
L14-30R
NEMA
L14-30P
Locking
Receptacle(REC4)
TABLE 1
WARNING
The duplex 120V receptacle is protected by a GFCI (Ground Fault Circuit
Interrupter). GFCI shuts off the output current from the duplex 120V
receptacle when a ground fault occurs in the generator or the appliance.
Please note that other receptacles are not protected by GFCI.
[
CAUTION
]