Stiga 75R-HX Tiller User Manual


 
46
ENGLISH
GB
The optimum working depth varies with soil con-
ditions. The working depth is determined by how
hard the depth skid is pushed down during propul-
sion. Operate and test.
Drive 2-3 times in different directions for best re-
sults.
Never operate the machine in wet soil. Clumps of
earth are created that are then difficult to break-up.
Hard and dry soil requires an extra run, at right an-
gles to the first.
WARNING! Never overload a new ma-
chine. Drive carefully for the first 5
hours.
6 STORAGE
Store the rotary cultivator in a dry place. Also see
section “Safety instructions”.
After draining the petrol, start the engine and allow
it to run until it runs out of petrol.
7 MAINTENANCE
WARNING!Repairs must be carried out
by the dealer. Otherwise the guarantee
becomes invalid.
WARNING!Before carrying out repairs
and maintenance, the spark plug con-
nection must be disconnected.
7.1 Periodic maintenance
Before each operation
Check for fuel leaks.
Check that all screws are tightened.
After each operation
Clean the rotary cultivator.
Check for fuel leaks.
Every 25 operating hours and every 3 months
Check, clean or replace the air filter.
Check that all screws and nuts are tightened.
7.2 Air filter
The air filter is shown according to the table be-
low:
Do not use flammable liquids when
cleaning.
Serious engine damage can be caused if
the machine is operated with a defective
or blocked filter.
The paper filter must never be cleaning
with liquid.
The machine is equipped with a pre-filter (foam
rubber) and a main filter (paper).
Clean/replace the air filter every 3 months or every
25 operating hours. During operation in dry and
dusty conditions, the air filter must be cleaned/re-
placed every day.
Clean/replace the air filter as follows:
1. Undo the screws or locking tabs and the filter
housing.
2. Grasp the main filter (paper) and shake it a few
times against a hard surface or blow clean with
compressed air from the inside out.
3. Wash the pre-filter (foam rubber) in liquid de-
tergent and water. Then carefully twist the filter
out and allow to dry.
4. When the pre-filter is dry, reinstall the filter in
reverse order.
The filters must be replaced if very dirty or defec-
tive.
7.3 Spark plug
The spark plug is shown according to the table be-
low:
The sparkplug must be replaced in the following
cases.
When the electrodes are burnt.
If the porcelain insulator indicates damage.
If the rotary cultivator is difficult to start.
The electrode gap should be 0.7-0.8 mm.
Use sparkplug Champion QC12YC or similar.
Machine Figure:Position
75-G 2:B
75R-B 9:B
75R-H 3:B
75R-HX 4:B
Machine Figure:Position
75-G 2:A
75R-B 9:A
75R-H 3:A
75R-HX 4:A