Sears 919 Portable Generator User Manual


 
ii
PROBLEM
EnsUewdJ'not=tart
No elecfK_aloutput
Repeatedcircuitbreaker
tripping
Genorator overheating the
circuit I_oaker depressed
i iii n ii
CAUSE
1. Low on fuel or o11.
2. Igrdtion switch In "Off' position.
3. Faultyep_k p|ug.
4. Choke Inwrong position.
5. Fuelshut-off valve in do_md
position.
8. Unit loaded during start-up.
7. Spark plug wire loose.
1. Faulty reaep_acla.
2, Circuitbreaker kicked out.
3. Oefectlve capacitor.
4. Faulty power oord,
5. GFCI receptacle c/muir breaker
kicked out.
1. Ovadoad
2. Faulty cords or equipment.
1. Generator overloaded.
2. Insufficient ventilation.
ii
CORRECT/ON
1. Add fuol or oil.
2. Tumto 'ON' polltlon
3. Replace spark plug.
4. Adjust choke accon:lingly.
5. Open fuel shut-off valve.
6, Remove load from unit.
7. Attach wire to spark plug.
1. HaveAuthodzed Sears Service
Center replace.
2. Depress and reset.
3. Have Authodzad Sears Service
Centor replace capacitor,
4. Repair or replace cord.
S, Det_mw and _et.
1. Reduce load.
2. Cheokfordamaged,bare,or
frayedwireson equipment.
Replace.
1, R_uoaload.
2. Move to adequate supply of
fresh air.
ii =l
19 -- ENG _u e,,,,.owL_o