Sears 919 Portable Generator User Manual


 
NOTE: No choke is required on wa_n ehginex. Mike
surechoke isin the "NO CHOKE" posRIon on warm
engine atal_,
[ I_KM,_UlIII[II¢I ¢ou Mus'r unplug any load
I lmll_lll:l from the geosr_or before
| tarring to prevent pern-4nent damage Io any
I applisn©es.
For electric start:
Plaoe OFFIRUN/START sw)tsh in the START
position.
NOTE: When the engine starl_ the switch will
remain in the RUN position.
F_ rm=_ sta_'.
Place OFFIRUN/STARI" switch in the RUN posi-
tion.
STOPPING ENGINE
Dlscoonect all elecffical loads.
* "nJrrlOFF/RUN/START switoh to 'oFF" position.
Cle=mfuel shut-off valve.
indoors, or in enclosed, poorly ventilated orees or
I
where fuel fum_ may reach an open {lame.
Grasp handle on rope starter lind pull slowly until
roslatance isfelt. Let the rope rewind slowly. Pull
rope with a rapid full arm stroke. Let rope rewind
slowly. Repeat if necessa W,
NOTE: IF ENGINE OIL LEVEL IS TOO LOW, EN-
GINE WILL NOT START. CHECK OIL LEVEL AND
ADD IF NECESSARY,
When engine warms up, gradually push choke
control In to the CHOKE posit!on.
IMPORTANT: Allow generator to run at no load
for 5 minutes upon eilch Initial start-up to allow
I
engine end generator to stabilize,
CONNECTING ELECTRICAL LOADS
Lat onglne mn and warm up for five minutes after
aterdng with noelectrical lead.
COnnect loads in the following manner to prevent
damage to equipment:
Connect inductive IoQdequipment first, inductive
loads oon_;at of refrigerators, freezers, water
pumps, air conditionem, or small handtoots.
Connect the items that requirethe most wattage
first.
Connect the lights next.
Voltage sensitive equipment should be the last
equipment oonnectad to the generator. Plug
voltage sensitive appliances such at TV's, VCR's.
mi_rowavos, over.s, oomputem, and cordless
telephones into a UL listed voltage surge protec-
tor, then oonne_t the UL Ilstad voltage surge
protector to the genmtor.
IMPORTANT: You should always add up the rated
watts of all lights,tools and appllan_s you are
powedng at one tim, Thistotal should not
exceed the rated oapacPffof you generator or
olmuit breaker rating of the receptaole supplying
power.
15 --L:NG O_4Nq,_oul_