Cheetah 10K.7 SCSI Product Manual, Rev. D 45
8.0 Installation
Note. These drives are designed to be used only on single-ended (SE) or low voltage differential (LVD)
busses. Do not install these drives on a high voltage differential (HVD) bus.
The first thing to do when installing a drive is to set the drive SCSI ID and set up certain operating options. This
is usually done by installing small shorting jumpers on the pins of connectors J2 and J6 on the PCBA (or J5-
Auxiliary on the LW model), or via the drive to host I/O signals on the LC model. Some users connect cables to
J6 or J5-Auxiliary and perform the set-up using remote switches.
Configure drive options
For option jumper locations and definitions refer to Figures 18, 19, and 20. Drive default mode parameters are
not normally needed for installation. Refer to Section 9.3.2 for default mode parameters if they are needed.
• Ensure that the SCSI ID of the drive is not the same as the host adapter. Most host adapters use SCSI ID 7
because ID 7 is the highest priority on both 8 and 16 bit data buses.
• If multiple devices are on the bus set the drive SCSI ID to one that is not presently used by other devices on
the bus.
• If the drive is the only device on the bus, attach it to the end of the SCSI bus cable. The user, system integra-
tor, or host equipment manufacturer must provide external terminators.
Note. For additional information about terminator requirements, refer to Sections 9.8 and 9.9.
• Set all appropriate option jumpers for desired operation prior to power on. If jumpers are changed after
power has been applied, recycle the drive power to make the new settings effective.
• Installation instructions are provided by host system documentation or with any additionally purchased drive
installation software. If necessary see Section 10 for Seagate support services telephone numbers.
• Do not remove the manufacturer’s installed labels from the drive and do not cover with additional labels, as
the manufacturer labels contain information required when servicing the product.
Formatting
Drives are shipped from the factory low level formatted with 512 byte sectors.
8.1 Drive ID/option select header
Figures 18 and 19 show views of the drive ID select jumper connectors. Figure 20 shows the option select
jumper connector for all models. Figure 18 shows the drive’s J5-auxiliary jumper connector. Both J5-auxiliary
and J6 have pins for selecting drive ID and for connecting the remote LED cable. Only one or the other should
be used, although using both at the same time would not damage the drive. The notes following the figures
describe the functions of the various jumper positions on the connectors J2, J5-Auxiliary and J6. Suggested
part number for the jumpers used on J2 is Molex 52747-0211 (Seagate part number 77679052). A bag with the
two jumper plug types is shipped with the standard OEM drives.