NOZZLE
THROTTLE
CABLE
WARNING:
Disconnect the spark plug wire before assembling parts.
Failure to do so could result in possible serious personal
injury.
ASSEMBLING THE BLOWER TUBES
See Figures 2 - 4.
�� Place a clamp on blower past the raised tabs. Assemble
the elbow tube onto blower by aligning raised tabs on
blower with slots on elbow. Tighten clamp onto elbow.
Attach bellows onto elbow tube by placing a clamp on
one end of the bellows then press bellows onto elbow
tube. Tighten clamp.
Place a clamp on other end of bellows. Press bellows
onto throttle control handle tube. Tighten clamp.
NOTE: The position of the throttle control handle may be
adjusted for comfort after the blower is strapped onto the
operator’s back.
Join the straight upper tube and nozzle together by align-
ing raised locking tabs on straight upper tube with the
raised locking slots on nozzle and twist to secure.
Assemble the connected lower tubes to the throttle
control handle tube by aligning raised locking tabs on
the throttle control handle tube with the raised locking
slots on connected lower tubes by twisting to secure.
NOTE: Check all locking connections after initial run to
ensure they are tightly secured.
Hold the throttle cable against the bellows and install the
cable ties. Cable ties should be tight enough to retain
the throttle cable to the bellows but still allow for move-
ment.
ASSEMBLY
BELLOWS
ELBOW
TUBE
Fig. 2
Fig. 3
Fig. 4
THROTTLE CONTROL
HANDLE TUBE (UPPER TUBE)
CABLE TIE
THROTTLE CONTROL
HANDLE TUBE (UPPER TUBE)
UPPER TUBE
THROTTLE
CONTROL
HANDLE TUBE
(UPPER TUBE)
TUBE CLAMP