3 Specifications
3.1 Power Supply Specifications
Power Supply Type Minimum
Input
Maximum
Input
Fuse
Rating
Maximum Power
Consumption
24 VDC 18 VDC 36 VDC 3.15A(T)
2
48 VDC 36 VDC 72 VDC 3.15A(T)
2
HI (88/300 VDC)
1
HI (120/240 VAC)
1
88 VDC
85 VAC
300 VDC
264 VAC
3.15A(T)
2
3 W
Notes: 1 – This is the same power supply for both AC and DC.
2 – (T) Denotes time-delay fuse
CAUTION:
For continued protection against risk of fire, replace only with same type and rating of
fuse.
3.2 Twisted-Pair Port Specifications
Parameter Specification Notes
Speed 10/100 Mbps Auto-negotiating
Duplex FDX / HDX Auto-negotiating
Cable-Type > Category 5 Shielded/Unshielded
Wiring Standard TIA/EIA T568A/B Auto-Crossover, Auto-polarity
Max Distance 100m
Connector RJ45
Isolation 1.5kV RMS 1-minute