Roberts Gorden HE-125 Patio Heater User Manual


 
HE-SERIES INSTALLATION, OPERATION AND SERVICE MANUAL
14
Table 3: Component Package Guide
Table 4: Accessories Package (03200001)
Additional tubing length may be added to heater. Tubing must be heat-treated, aluminized or porcelain
coated. Any additional tubing lengths are considered as vent length for length determination. Maximum
venting length for minimum heater length is 45' (13.7 m) total.
Model Tubing Length
Core and Extension Packages
Aluminized Stainless Steel
HE-40 10' (3 m) CP10ALUM CP10ALUMSS
HE-60 20' (6 m) CP20ALUM CP20ALUMSS
HE-80 20' (6 m) CP20ALUM CP20ALUMSS
HE-100 30' (9 m) CP30ALUM CP30ALUMSS
HE-125 40' (12 m) CP40ALUM CP40ALUMSS
HE-150 50' (15 m) CP30ALUM + EXP20ALUM CP30ALUMSS+ EXP20ALUMSS
HE-175 60' (18 m) CP30ALUM + EXP30ALUM CP30ALUMSS + EXP30ALUMSS
Part No. Description Quantity
90502300 4" Metalbestos Vent Cap 2
90502700 Vent Adapter 1