MAINTENANCE
DB150 07/11 Maintenance Section 5-7
©2011 Alamo Group Inc.
MAINTENANCE
DRIVELINE LUBRICATION
Grease Fittings are located on the Cross Assembly of each U-Joint and on the telescoping tubes. Grease U-
Joint after each 8 hours of use. Figure Mnt-0024. Do not force grease through the Needle Cup Assemblies.
Grease the telescoping tubes after every 8 hours use. Some PTO-to-Hitch connections may necessitate
cutting a hole in the shields to be able to align the Grease Fitting holes for lubrication. Lubricate the shield
bearings every 16 hours. Figure Mnt-0026.