2.3.a Grounding
A single point ground connection is located in the lower right hand side of the
StarInverter cabinet. The PV panel grounding wire is terminated there. The AC
ground connection is terminated next to the Line and Line 2/Neutral connections
on the circuit board. The PV ground is bolted to the cabinet with a ¼-20 bolt.
(Refer to Figure 7.)
Figure 6 includes schematic representations of the PVP1800, and PVP2800 single
point grounding. The front cover is grounded through the two cover mounting
screws.
Line
Filter
Control pcb
Power Distribution PCB
DC
Power
Suppl y
L1
N
GND
PV GND
20 A SB
System Block Diagram
120 VAC
60Hz
120-360 VDC
PV
DC input
PVP 1800
-
+
GND
15A
1A
Line
Filter
Control pcb
Power Distribution PCB
DC
Power
Supply
L1
L2
GND
PV GND
15 A SB
S