Redring 620 Outdoor Shower User Manual


 
Check the spray plate is then free to rotate to give the three settings.
In some winter conditions, when the incoming mains water is particularly cold it may be necessary
to select the inner or outer spray pattern only. This will ensure correct operation of the shower with
a slightly lower water flow rate
Note: After use it is normal for some water to drip from the showerhead for a few moments, this
inhibits scale build up over prolonged use.
What to do if things go wrong
SELF HELP
If the shower is unsatisfactory, make the following checks before calling out the contractor. Any of
these adjustments could restore the performance
a) Water too HOT
Increase water flow by adjusting the
temperature control clockwise.
Clean spray plate holes. (Select outer or
combination spray patterns).
Switch power to MEDIUM setting.
Increase pressure of water supply e.g. fully
open service valve or stop cock. Check hose is
not kinked restricting the water flow.
b) Water too COLD
Decrease water flow by adjusting the
temperature control anti-clockwise.
Select inner or outer spray patterns only.
Switch power to HIGH setting.
c) Spray pattern poor
Clean spray plate and flush heater. (Select
inner / outer spray pattern).
d) Water goes cold while using shower
Check water pressure has not fallen so far as
to let pressure switch cut out, e.g. another tap
drawing water off.
Raise position of handset.
e) Broken parts
Please contact our spares department on
0870 0102 829.
Fitting instructions are provided with spares.
PROFESSIONAL SERVICE
If the previous checks fail to restore the performance, you should either contact the Redring
Technical Advisory Service or seek the assistance of a qualified plumber and / or electrician.
The person who installed the shower is probably the best one to repair it and is certainly
the person to contact if you have a problem in the guarantee period.
The following additional checklist is provided for the benefit of the qualified serviceman.
WARNING – SWITCH OFF THE ELECTRICITY AT THE ISOLATING SWITCH BEFORE
REMOVING THE COVER TO MAKE CHECKS.
5