Quantum Data 882E Portable Generator User Manual


 
36 882E Quick Start Guide - HDCP Compliance Testing with Encryption Status Tester (EST) - P/N 68-00210 Rev. B
To run the 3C-II series HDCP compliance tests on an HDMI repeater:
The 3C-II-01 test is run for each of the two read configurations: 1) short read and 2)
combined read. These multiple iterations are handled in the batch mode but you can
choose to run them through the command line as well.
1. Connect the cables as follows:
a. Apply power to the Encryption Status Tester (EST) using the power adapter
supplied with the EST.
b. Connect an HDMI cable from the repeater device under test input to the EST HDMI
port labeled, “HDMI OUT.”
c. Connect an HDMI cable from the 882 HDMI Rx 1 port to the HDMI output of the
repeater device under test.
d. Connect an HDMI cable from the 882 HDMI Tx 1 port to the EST HDMI port labeled
“HDMI IN.”
e. Connect an HDMI cable from the 882 HDMI Tx 2 port to the EST HDMI port labeled
“HDMI.”
The following diagram depicts the test setup for the 882EA:
35 3C_I_06 (Repeater Upstream
w/Transmitter) (Between HDMI
Capable Transmitter and HDMI
Capable Receiver)
Irregular Procedure: (Second Part of
Authentication) Verify Bksv
36 3C_I_07 (Repeater Upstream
w/Transmitter) (Between HDMI
Capable Transmitter and HDMI
Capable Receiver)
Irregular Procedure: (Second Part of
Authentication) Verify R0'
CPTX:CPTR
I
ndex Test Description