14 882E Quick Start Guide - HDCP Compliance Testing with Encryption Status Tester (EST) - P/N 68-00210 Rev. B
Running HDCP compliance tests on HDMI receivers
For the 882E the 2C-01 and 2C-04 tests are run multiple times for various settings. The
2C-01 test is required to be run in two configurations: 1) combined reads and 2) short
reads. The 2C-04 test is required to be run in six (6) configurations. There are two read
configurations: 1) short read and 2) combined read and there are three encryption pulse
configurations: 1) in the beginning of the vertical blanking; 2) in the middle of the vertical
blanking and 3) at the end of the vertical blanking.
These multiple iterations are handled in the batch mode but you can choose to run them
through the command line as well.
To run the 2C series HDCP compliance test on an HDMI sink (receiver):
1. Connect the cables as follows:
a. Apply power to the Encryption Status Tester (EST) using the power adapter that is
supplied with the EST.
b. Connect an HDMI cable from the sink device under test input to the EST HDMI port
labeled, “HDMI OUT.”
c. Connect an HDMI cable from the 882 HDMI Tx 1 port to the EST HDMI port labeled
“HDMI IN.”
d. Connect an HDMI cable from the 882 HDMI Tx 2 port to the EST HDMI port labeled
“HDMI.”
The following diagram depicts the test setup: