Predator Tools 61725 Portable Generator User Manual


 
Page 18 For technical questions, please call 1-888-866-5797. ITEM 61725
SAFETY OPERATION MAINTENANCESETUP
Starting the Engine
Before starting the engine:
a. Inspect the generator and engine.
b. Disconnect all electrical loads from the generator.
c. Fill the engine with the proper amount and type of both unleaded gasoline and oil.
1. To start a cold engine, pull the START Knob out
to the START position.
To restart a warm engine, push the START Knob in
to the RUN position.
2. Open the Fuel Valve.
3. Turn the Engine Switch to START.
4. Allow the Engine to run for several seconds.
Then, if the START lever is in the START position,
move the START Lever very slowly to its RUN position.
Note: Moving the START Lever too
fast could stall the engine.
IMPORTANT: Allow the engine to run at no load for five minutes with no
load after each start-up so that the engine can stabilize.
5. Adjust the Throttle as needed.
Break-in Period:
a. Breaking-in the engine will help to ensure proper equipment and engine operation.
b. The break-in period will last about 25 hours of use. DO NOT exceed
75% of the Generator’s rated capacity during this period.
• Change the engine oil after this period.
Under normal operating conditions subsequent maintenance follows
the schedule explained in the MAINTENANCE section.
1
2
3
ON
OFF START
4
OFF
ON