Pentair 620001 Landscape Lighting User Manual


 
P/N 620001 16 Rev. A 1-18-06
Alternate Repair Instructions
STEP 8
1. Completely cover the entire entry hub and the jumper wire connection with two parts of underwater epoxy
putty, (supplied with this kit), to at least 1/4 inch thickness.
a. If a jumper wire is connected to the bonding lug in the fixture housing cover this connection with a listed
potting compound, (Scotchcast 2134 or equivelant).
b. This will require the pool water level to be lowered and the potted area dried.
c. Allow 30 minutes prior to applying the epoxy putty.
2. Do not cover the anode block.
3. Allow the light fixture cord to move freely within the putty.
NOTE
Cord must move freely within the putty to allow the removal of the light fdixture should it ever need repair or replacement.
SAVE THESE INSTRUCTIONS.
hn-11-11-16-98
Do not cover
anode block with
potting
compound.
Potting Compound