Pentair 620001 Landscape Lighting User Manual


 
P/N 620001 10 Rev. A 1-18-06
Working with muriatic acid can be dangerous. When cleaning elements always wear rubber gloves
and eye protection. Add acid to water, do not add water to acid. Splashing or spilling acid can cause
severe personal injury and/or property damage.
WARNING
1. If there is no internal bond wire as shown, skip to STEP 6.
2. If there is an internal bond wire with a non-listed potting material around the bond post, remove the potting
material completely. A non-listed potting material would be silicone, RTV, etc.
a. Be very careful not to damage the No. 8 bond wire, the screw or the post.
3. Replace the bond wire or the bonding screw if it is damaged. Then, go to instruction STEP 3 and complete the
procedures through STEP 5.
Alternate Repair Instructions
STEP 2
hn-02-11-16-98
Fixture 2.
Light Fixture
Cord
Internal Bond
Wire
Remove bonding
lug non-listed
potting material if
present, check
that screw is
tight.